AC-CDI 90S1200

[ARCHIVE] A project from  adresse mail !

 

Characteristics.

  • CDI type
  • monocylinder
  • Need a battery
  • 5 advances curves in memory
  • Maximum RPM: 10.000rpm
  • Digital tachometer temperature display.
  • Temperature measurement (20° to 150°C)
  • Alarm on maximum temp. and max rpm.
  • Adjustable position of the pickup (35° by default)
  • Accuracy: 1.2° at 10.000rpm
  • Software source available (.ASM).

 

Advance curve.

Each curves are defined by 2 couples of values:
One couple [ rpm – advance] for low rpm
One couple [ rpm – advance] for high rpm

Curve 0: 8° at 1000 rpm and 35° at 6000rpm
Curve 1: 8° at 1000 rpm and 35° at 5500rpm
Curve 2: 8° at 1000 rpm and 35° at 5000rpm
Curve 3: 8° at 1000 rpm and 35° at 4500rpm
Curve 4: 8° at 1000 rpm and 35° at 4000rpm

Instructions  (French)

 

Software.

Source
ASM – HEX
Excel
CDI à ATMEL
pour
Daelim VT600R
CDI_V1.52.ZIP Calcul_rampes.XLS


Replacing AT90S1200 by ATtiny2313

 

Schematic.

Schéma Circuit imprimé Implantation Liste des composants
CDI à ATMEL
pour
Daelim VT600R
Scheme.PDF Circuit board.PDF Layout.PDF Components.XLS

 

Pics.

Zoom. Zoom.
Zoom. Zoom.

1 thought on “AC-CDI 90S1200”